Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Journal of Biomedical Engineering ; (6): 695-698, 2006.
Article in Chinese | WPRIM | ID: wpr-249524

ABSTRACT

To develop a filtering algorithm which could trace the spectral peaks of the interference and which was used to extract the breath signal with the same band interference in radar non-contact life-detecting system, second filtering algorithm was studied. Through first filtering,the probable interfering spectral peaks (ISP) could be detected by Yule-Walker spectrum estimating and could be located by calculating the coefficients of normalized cross-correlation function according to standard breath signal. Thus the breath signal could be extracted through a second filtering. By using the second filtering algorithm (SFA), the same band interfering spectral peaks with breath signal could be recognized and inhibited. So we conclude that the same band mono-ISP could be inhibited by using SFA and breath signals could be effectively extracted.


Subject(s)
Adult , Humans , Male , Algorithms , Artifacts , Monitoring, Physiologic , Methods , Radar , Signal Processing, Computer-Assisted
2.
Journal of Biomedical Engineering ; (6): 749-752, 2004.
Article in Chinese | WPRIM | ID: wpr-342620

ABSTRACT

The non-contact life parameters detecting systems can detect many important life parameters such as heartbeat and breathing at certain distance. In practice, the self-dithering interference of the system is produced by some factors; it makes the signal-to-noise ratio (SNR) of the recorded signal lower. This paper is discussed an adaptive technology based on a variable step-size LMS algorithm, which is used to eliminate the self-dithering interference of the system and hence to raise the SNR of the detecting signal. A method to obtain the reference signal by vibration sensor is brought forward and the optimum parameters settings are discussed. The results show that the reference signal is an integral part of output signal of the vibration sensor and has a relationship with the setting direction of the sensor. The conclusion is that the method is effective and feasible; also the algorithm is well convergent.


Subject(s)
Algorithms , Data Interpretation, Statistical , Electrophysiology , Methods , Equipment Design , Heart Rate , Physiology , Models, Biological , Reference Values , Respiration , Signal Processing, Computer-Assisted , Software
3.
Chinese Medical Equipment Journal ; (6)2004.
Article in Chinese | WPRIM | ID: wpr-587121

ABSTRACT

Objective To build finite-element models of cerebral hemorrhage on which a simulation study of electrical impedance tomography(EIT) is based.Method With a kind of four-layer concentric circle model of head,finite-element method and dynamic NOSER algorithm are performed to reconstruct the images.Result As to the single-focus model of the cerebral hemorrhage,the focus can be clearly imaged,while to the several-focus model,the focuses can be imaged with vaguely adjacent boundaries.Conclusion The dynamic NOSER algorithm is an effective method to image cerebral hemorrhage in EIT.

4.
Chinese Medical Equipment Journal ; (6)2003.
Article in Chinese | WPRIM | ID: wpr-583308

ABSTRACT

This paper introduces the means and characteristics of signal acquisition of the non-contact life parameters detection system as well as the design of preprocessor circuit.The results show that the preprocessor is designed reasonably,which can provide the computer with high quality signals.

SELECTION OF CITATIONS
SEARCH DETAIL